 VOLTAGE RANGE 50 to 1000 Volts CURRENT 1.0 Ampere
FEATURES
* * * * * * Glass passivated device Ideal for surface mounted applications Low leakage current Metallurgically bonded construction Mounting position: Any Weight: 0.015 gram
SURFACE MOUNT GLASS PASSIVATED SILICON RECTIFIER
SM4001 THRU SM4007
MECHANICAL DATA
DISCONTINUED-
* Epoxy : Device has UL flammability classification 94V-0
D
co is
ed inu nt
.205 ( 5.2 ) .190 ( 4.8 ) SOLDERABLE ENDS
MELF
"This series is replaced by the FM400X series that meets to the same fit and function parameters and share the same solder pad layout. The FM400X series is preferred for error-free vacuum pick-up and PCB assembly."
.024 ( 0.6 ) .016 ( 0.4 ) .106 ( 2.7 ) .095 ( 2.4 )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 OC ambient temperature unless otherwise specfied. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%. Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) RATINGS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at Ambient Temperatur e Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Thermal Resistance (Note 1) Typical Thermal Resistance (Note 1) Typical Junction Capacitance (Note 2) Operating Temperature Range Storage Temperature Range
O
SYMBOL VRRM VRMS VDC IO I FSM RqJA RqJC CJ TJ T STG
SM4001
SM4002
SM4003
SM4004
SM4005
SM4006
SM4007
UNITS Volt s Volt s Volt s Amps Amps
0 0
50 35 50
100 70 100
200 140 200
400 280 400 1.0 30 50 20 15 150 -55 to + 150
600 420 600
800 560 800
1000 700 1000
C/W C/W pF
0 0
C C
ELECTRICAL CHARACTERISTICS (@TA=25 C unless otherwise noted) CHARACTERISTICS Maximum Instantaneous Forward Voltage at 1.0A DC Maximum Average Reverse Current at Rated DC Blocking Voltage @T A = 25 o C @T A = 100 C
o
SYMBOL VF IR
SM4001
SM4002
SM4003
SM4004
SM4005
SM4006
SM4007
UNITS Volt s uA uA 2007-3
1.1 5.0 100
NOTES : 1. Thermal Resistance :Mounted on PCB. 2. Measured at 1 MHz and applied reverse voltage of 4.0 volts. 3. "Fully ROHS compliant","100% Sn plating (Pb-free)".
RATING AND CHARACTERISTICS CURVES ( SM4001 THRU SM4007 )
INSTANTANEOUS FORWARD CURRENT, (mA)
AVERAGE FORWARD CURRENT, (A)
2.0
1000 100 TA = 100 OC 10 1.0 0.1 0.01 0
TA = 75 OC TA = 25 OC
1.5
1.0
0.5
Single Phase Half Wave 60Hz Resistive or Inductive Load 0.375" (9.5mm) Lead Length
0
0
25
50
75
100
125
150
175
20
40
60
80
100
120
140
AMBIENT TEMPERATURE, (OC)
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
INSTANTANEOUS REVERSE CURRENT, (A)
10
CJ, JUNCTION CAPACITANCE, (pF)
20
FIG.1 TYPICAL FORWARD CURRENT DERATING CURVE
40 20 10 8 6 4 2 1
FIG.2 TYPICAL REVERSE CHARACTERISTICS
TJ = 25 OC
1.0
0.1
TJ = 25 OC Pulse width=300 S 1% Duty Cycle
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0.1
0.4
1.0
4
10
40 80
INSTANTANEOUS FORWARD VOLTAGE, (V)
REVERSE VOLTAGE, (V)
FIG.3 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS
PEAK FORWARD SURGE CURRENT, (A)
FIG.4 TYPICAL JUNCTION CAPACITANCE
30 25 20 15 10 0 1
8.3mS Single Half Sine-Wave JEDEC Method
2
4
6
8 10
20
40
80 100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
Mounting Pad Layout
.100 (2.54)
F-SLOT WIDTH OPTIMUM PAD SIZE
.100 (2.54)
.100 (2.54)
.200 (5.08)
.300 (7.62)
Dimensions in inches and (millimeters)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.


▲Up To Search▲   

 
Price & Availability of SM4007

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X